CCYGY - CIMPERIAL 1011, GREEN 087
- MSDS: CCYGY
- Manufacturer: CINCINNATI MILACRON MARKETING CO
- Product Name: CIMPERIAL 1011, GREEN 087
- National Stock Number: 9150-00N040009
Product Identification
Product ID:CIMPERIAL 1011, GREEN 087
MSDS Date:06/01/1992
FSC:9150
NIIN:00N040009
MSDS Number: CCYGY
Responsible Party
CINCINNATI, OH 45209
US
Emergency Phone: 513-841-8181
Info Phone: 513-841-8964
Cage: 12356
Contractor
Telephone: 513-841-8964
Cage: 12356
Ingredients
BUNGS IN PLACE. DO NOT REUSE BEFORE COMMERCIAL
RTECS: 9999999ZZ
TOGETHER/VENT IS INADEQ, OPERATORS MAY EXPERIENCE RESP
RTECS: 9999999ZZ
MIST COLLECTORS IS RECOMMENDED.
RTECS: 9999999ZZ
MINERAL OIL, PETROLEUM DISTILLATES, HYDROTREATED (SEVERE)
CAS: 64742-52-5
RTECS: PY8035001
Fraction By Weight: 80%
OSHA PEL N/K
ACGIH TLV: N/K
ETHANOL, 2,2',2"-NITRILOTRI-; (TRIETHANOLAMINE)
CAS: 102-71-6
RTECS: KL9275000
Fraction By Weight: 10% MAX
OSHA PEL N/K
ACGIH TLV: 5 MG/M3
NONYLPHENOL POLYETHOXATE; (NONYLPHENOXY-POLYETHOXYETHANOL)
CAS: 9016-45-9
RTECS: 9999999VO
Fraction By Weight: 10%
OSHA PEL N/K
ACGIH TLV: N/K
RSLT FROM CONT W/CONCENTRATED PROD. SKIN IRRIT CAN
RTECS: 9999999ZZ
IF CONCENTRATE/MIX IS SWALLOWED, DO
RTECS: 9999999ZZ
IMMED CONT PHYS & OBTAIN TREATMENT. SWALLOWING SM
RTECS: 9999999ZZ
ILLNESS; BUT, AS SHOULD BE EXPECTED WHEN DRINKING
RTECS: 9999999ZZ
NOT EXPECTED TO BE PROBABLE ROUTE
RTECS: 9999999ZZ
CAN OCCUR IN APPLICS WHERE HIGH MIST LEVS ARE
RTECS: 9999999ZZ
PARTICULATE AS NUISANCE LEVEL OF EXPOSURE.
RTECS: 9999999ZZ
WHICH IS NOT CONSIDERED HAZ WASTE UNDER
RTECS: 9999999ZZ
INVERSION & CAN BE OFFERED FOR RECYCLING/SCRAP.
RTECS: 9999999ZZ
CAN BE DANGEROUS IF USED TO STORE TOX, FLAM/REACTIVE
RTECS: 9999999ZZ
FIRE, EXPLO/TOX FUMES FROM RESIDUES. DO NOT
RTECS: 9999999ZZ
2-BIPHENYLOL; (2-PHENYLPHENOL) (SARA 313)
CAS: 90-43-7
RTECS: DV5775000
Fraction By Weight: 5%
OSHA PEL N/K
ACGIH TLV: N/K
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:PROD @ USE
DILUTION:INHAL:EXTENDED EXPOS TO MISTS MAY CAUSE UPPER RESP IRRIT.
EYE:WILL CAUSE STINGING SENSATION. SKIN:NOT IRRITATING TO SKIN WHEN
USED AS DIRECTED & GOOD PERSONAL HYGIENE IS PRAC TICES.
INGEST:SWALLOWING SM QTYS MAY CAUSE NAUS/DIARR. WHEN USED IN APPLIC
GENERATING HIGH LEVELS OF (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:MIST, OPERATOR EXPOS CAN BE MINIMIZED
BY PROPER VENT, USE OF MIST COLLECTORS/SPLASH GUARDS, AS APPROP. IF
THERE IS DOUBT ABOUT ACTUAL MIST LEVS PRESENT, MONITORING SHOULD BE
CONDUCTED. MILD S KIN IRRIT (REDNESS & DRYNESS OF HANDS) MAY BE
EXPERIENCED WHEN DILUTED PROD HAS BEEN CONTAMD BY CERTAIN OILS,
(SUPDAT)
Medical Cond Aggravated by Exposure:MAY AGGRAVATE EXISTING SKIN
IRRITATION WHERE FURTHER DEFATTING OR SKIN PENETRATION COULD OCCUR.
First Aid
First Aid:EYES:CONT W/CONCENTRATED PROD/DILUTED MIX, FLUSH IMMED
W/RUNNING WATER FOR @ LST 15 MINS, THEN PROMPTLY GET MED ATTN TO
CHECK FOR POSS IRRIT. SKIN:CONT W/PROD CONCENTRATE, WASH W/WATER AS
SOON AS POSS . DILUTED PROD IS NOT IRRITATING TO SKIN WHEN USED AS
REC & GOOD PERSONAL HYGIENE IS PRACTICES. REMOVE SEV CONTAMD CLTHG,
INCL SHOES. LAUNDER BEFORE REUSE. IF IRRIT PERSISTS, GET MED ATTN.
(ING 7)
Fire Fighting
Flash Point Method:COC
Flash Point:370F,188C
Extinguishing Media:FOAM, CARBON DIOXIDE.
Fire Fighting Procedures:NONE. USE NIOSH APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE. HAZARDOUS COMBUSTION
PRODUCTS:SMOKE, FUMES AND OXIDES OF CARBON.
Accidental Release
Spill Release Procedures:CONTAIN SPILL, COLLECT ON ABSORBENT MATERIAL
AND DISCARD AS DICTATED BY FEDERAL, STATE AND LOCAL REGULATIONS
THAT MAY APPLY. FLUSH AREA THOROUGHLY WITH WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:USE ONLY AS REC BY MFR. AVOID ALL CONT
OF CONCENTRATE W/EYES OR SKIN. DO NOT SWALLOW. COMBUSTIBLE LIQUID.
AVOID OPEN FLAMES, SPKS, & TEMPS >370F.
Other Precautions:IF FROZEN, THAW COMPLETELY @ ROOM TEMP. CONTAINS
AMINES. DO NOT ADD SODIUM NITRITE/OTHER NITROSATING AGENTS TO THIS
RPOD. SUSPECTED CANCER CAUSING NITROSAMINES COULD BE FORMED.
Exposure Controls
Respiratory Protection:PRODUCT IS NOT VOLATILE. NIOSH APPROVED
RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN .
Ventilation:FOR MOST APPLIC, NORM SHOP VENT IS ADEQ. HOWEVER, WHEN HIGH
MIST LEVS ARE GENERATED/WHERE MACHINES ARE CLOSE (ING 18)
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPRVD EYE WASH & DELUGE SHOWER .
EFTIVE METALWORKING PLANT PROTECTIVE CLOTHING AS APPROPRIATE.
Work Hygienic Practices:GOOD PERSONAL HYGIENE SHOULD ALWAYS BE
FOLLOWED.
Supplemental Safety and Health
PH (CONCENTRATE):NOT APPLICABLE. PH (5% MIX):8.8-9.2. EFTS OF
OVEREXP:BY DISSOLVED METALS/WHEN MIX RATIO IS TOO STRONG. WHEN
PROBLEMS OCCUR, USE OF WATER-RESIST BARRIER CREAMS MAY BE TEMPORARY
CONTROL MEASURE. CONT MFR TECHNICAL SERVICES (513-841-8133) FOR
SPECIFIC REC. SIGNS & SYMPS OF EXPOS:EYE INJURY MAY (ING 6)
Chemical Properties
Spec Gravity:1.0054-1.0154
Evaporation Rate & Reference:LIKE WARM WHEN DILUTED
Solubility in Water:MISCIBLE
Appearance and Odor:HAZY/EVERGREEN OR SASSAFRAS.
Stability
Stability Indicator/Materials to Avoid:YES
AVOID CONTACT WITH STRONG OXIDIZERS.
Stability Condition to Avoid:NOT APPLICABLE.
Hazardous Decomposition Products:SMOKE, FUMES, OXIDES OF CARBON.
Disposal
Waste Disposal Methods:FOR USED MIX:DISP PROC MUST COMPLY W/LOC,
COUNTY, ST & FED REGS. IF PRE-TREATMENT IS NEEDED, CHEM EMULSION
BREAKING/ULTRAFILTRATION MAY BE USED. CONT MFR TECHNICAL SERVICES
(513-841-8133) FOR ASSISTAN CE. "EMPTY" CNTNRS WILL CONTAIN
RESIDUE(ING 13)
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.